Specifications
5 compute nodes, each with:
Processor: 1.0 GHz Freescale MPC8640D
Processor bus: MPX bus at 500 MHz
Memory: 2-GB DDR2 SDRAM
Memory speed: 500 MT/s (267 MHz DDR)
DRAM bandwidth: 8.0 GB/s
Flash memory: 128-MB EEPROM
Switch fabric: Dedicated 4x serial RapidIO interface at 3.125 Gbaud
Switch fabric
Protocol: 4x serial RapidIO at 3.125 GBaud (ISO/IEC DIS 18372)
Bandwidth: 1.25 GB/s in each direction, 5.0 GB/s to the backplane
Gigabit Ethernet secondary fabric
Protocol: 1000BASE-X (IEEE-802.3)
Connections: To SFM7180 Modules 1, 2, and 4
Front-panel connections
1 Gigabit Ethernet port to CN1 (Compute Node 1)
5 RS-232 serial ports to each CN (for debug use)
Electrical/Mechanical
Input voltage: 48 VDC
Power: 180W typical max
Dimensions: M155 format
Slot spacing: 1.015 in
Environmental *
Commercial
Minimum airflow/slot
28 CFM, stacked configuration at sea level
Temperature
Operating: 0°C to 35°C
Altitude
Operating: Sea level to 10,000 ft
MTBF
Calculated using MIL standard 217F
(Consult factory for Mil 217F reliability data)
*As altitude increases, air density decreases and, therefore, the cooling effect of a particular number of CFM decreases. Different limits can be achieved by trading among altitude, temperature, performance, and airflow. Contact Mercury for more information.