Specifications
Electrical Specifications
Availability and Serviceability
Internal bus: I2C/IPMB, 100 Mbit Ethernet
External bus: 100 Mbit Ethernet
Power Input
180-264 VAC, 47-63 Hz, 3Ø
NEMA L21-30P inlet
Note: Maximum power draw for fully configured system with 1.0 GHz processor boards is estimated as 4.2 kW.
Commercial Environment
Humidity
Operating: 5-90% non-condensing
Non-operating: 5-95% non-condensing
Temperature
Operating: 5°C to 35°C at max of 6,000 ft
Non-Operating: -40°C to +70°C at max of 35,000 ft
Contact Mercury for rugged system specifications.
As altitude increases, air density decreases, hence the cooling effect of a particular CFM rating decreases. Notice that the above operating temperature is specified simultaneously with an altitude. Different limits can be achieved by trading among altitude, temperature, performance, and airflow.
Contact Mercury for more information.
Configuration Options
Processors: 20-120 compute nodes
Bandwidth: 15-60 GB/s bisection bandwidth
Mezzanines: 2-64 serial FPDP interfaces