Specifications
Dual Cell BE Processors
PPE core: IBM® 64-bit Power Architecture™
L1 cache size: 32 KB instruction; 32 KB data
L2 cache size: 512 KB
SPEs: 8
Local store: 256 KB
Registers: 128 x 128 bits wide
EIB: 205 GB/s sustained aggregate bandwidth
Processor internal clock speed: 3.2 GHz
Processor-to-memory bandwidth: 25.6 GB/s
Processor-to-processor coherent interface: 20 GB/s in each direction
Memory
XDR memory
Each processor: 1-GB, 3.2-GHz XDR DRAM, 2 channels per processor
DDR2 memory
Each processor
1 or 2 GB, 667-MHz DDR2 organized as 2 VLP DIMMs per processor,
1 channel per DIMM (optional)
ECC support: Single-bit correct; double-bit detect on XDR and DDR2
Flash: 32 MB
NVRAM: 1 MB
Hard Disk (Optional)
Hard disk controller
SAS Controller via PCIe plugin card (consumes one slot)
Number of hard disks: 1 (maximum)
I/O Subsystems
Serial ports: 2 (one dedicated for management functionality)
USB ports: 2
Ethernet ports: 2 10/100/1000 Mb
Supports advanced RAS system management via a dedicated Ethernet connection.
InfiniBand® option
10 Gigabit Ethernet option
Expansion Options (Optional)
Plugin cards
2 PCIe x16 mechanical, x8 electrical full-size cards
25W maximum; consult factory for higher power cards
PCIe extender
System Management
System Management Module
Baseboard Management Controller
MultiCore Plus SDK Software (Optional)
(32/64-bit application support)
MCF (MultiCore Framework): PPE/SPE
TATL™ (Trace Analysis Tool and Library): PPE/SPE
SAL (Scientific Algorithm Library): PPE/SPE
PixL™ (Image Processing Algorithm Library): PPE
MCPDIAGS (MultiCore Plus Diagnostics): PPE/SPE
SPEAD-K (SPE Assembly Development Kit): SPE
Linux operating system
Size
Length: 30 in
Width: 17.15 in (19-inch EIA rackmount)
Height: 1.73 in (1U)
Airflow
Required: <90 CFM @ MSL
Noise
Acoustical noise: <50 dBA @ 1 m
Electrical
100-240 VAC, 50/60 Hz
Power Consumption
Maximum: 700W
Typical: 575W
Weight
<45 lb
Environmental
Ambient temperature: 0°C to 35°C
Humidity: 5-80% non-condensing
Altitude: 7,000 ft at 32°C
*Maximum ambient temperature is de-rated to 32°C beginning at 3000 ft.
Compliance
European Directive 2002/95/EC
(RoHS 5/6 Server Exemption Directive)
Safety; UL/EN/IEC 60950-1 (intended)
EMC: EN 55022, EN 61000, EN 55024:1998, FCC Class A